Category Archives: DIY

Catnic Cougar Open Back Cavity Wall Standard Duty Lintel 1500mm CG150/100

Open Back Cougar Lintels are for use in Cavity Wall construction. The lintels incorporate insulation, built-in plaster key and DPC. The lintels supports uniform distribution of masonry loads, timber floors and roof loads. Also suitable for fair faced inner leaf masonry. Easy to use Cougar open back profile 150-165mm Cavity, 100-115mm Inner Leaf Duplex corrosion protection Built-in Plaster Key Built-in DPC Continuous insulation

Supreme Prestressed Textured Concrete Lintel 100mm x 140mm x 900mm R15

Precision made, high performance structural concrete lintels Lintels are designed and manufactured in accordance with BS 5977; Part 2; 1983 Declaration of Performance available at www.supreme-ce.co.uk Harmonized Technical Specification EN 845-2:2013 Order in singles. See Tech Spec for pack quantity. This product isn’t available for delivery in Scotland

Catnic Cougar Open Back Cavity Wall Standard Duty Lintel 1500mm CG90/100

Open Back Cougar Lintels are for use in Cavity Wall construction. The lintels incorporate insulation, built-in plaster key and DPC. The lintels supports uniform distribution of masonry loads, timber floors and roof loads. Also suitable for fair faced inner leaf masonry. Duplex Corrosion Protection Built-in DPC Integral Plaster Key Integral Insulation Formed from galvanised steel then powder coated Easy to use Cougar open back profile Continuous insulation Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at 3000mm-3600mm

Heatrae 95050469 Megaflo Eco Unvented Cylinder Indirect 210L

Unvented hot water cylinder, supplying mains pressure hot water, suitable for all domestic applications. Lifetime cylinder guarantee Constructed from Duplex stainless steel pressure tested to 15 bar Patented internal floating baffle system to accommodate water expansion Unique ‘L-shaped’ long-life Superloy immersion heater Titanium immersion heaters as standard on all direct models High performance ‘coil-in-coil’ heat exchanger Improved 60mm insulation for maximum heat retention Made in the UK New water inlet controls increase flow rates by up to 20% Insulated casing for the temperature and pressure relief valve to minimise heat loss

4TRADE 6242YH 1.5mm Twin & Earth Cable Grey 10m

4Trade 1.5mm 6242Y Twin & Earth Cable Grey 10m. BASEC approved. Suitable for heavy duty lighting circuits Comprises two sheathed conductors (Live and Neutral) and an unsheathed protective conductor (Earth) BASEC Approved BS 6004:2012 Max. Rating: 240V, 14.5A Maximum operating temperature: 70¡C Flat for easy installation Easy to strip

60mm x 1200mm x 450mm Celotex PIR Cavity Wall Insulation Board CW4000

Celotex CW4000 is an easy to install polyisocyanurate (PIR) insulation board with excellent thermal performance, featuring a low emissivity foil facing. Available in thicknesses from 40mm to 100mm, it can be considered for use in partial fill cavity wall applications. Excellent thermal performance with a thermal conductivity of 0.022 W/m.K, reducing the thickness of insulation required to hit the target U-value. Low emissivity foil facing provides improved thermal performance in sealed cavity air spaces, improving the achievable U-value. The boards are light and rigid assisting with ease of transportation, handling and fitting. They are sized to fit standard wall tie spacing for ease of installation. Has been assessed by the BBA as fit for use in defined partial fill cavity wall applications if installed, used and maintained as set out in the certificate. Please read the certification at insulation-UK.com/BBA for full details and restrictions. To ensure we are providing you with the most up to date information available please visit our Manufacturer Technical Information page

Wienerberger Facing Brick Denton Sahara Buff – Pack of 400

Fine sanded, cream bodied fireclay drag wire Selected for its high quality aesthetic appearance Conforms to BS and EU Standards Durability meets F2 rating for severe exposure Low Salt Content – S2 Occasionally there can be a lead time on bricks from the manufacturer. If this is the case, we will let you know as soon as possible

Hygiclad Sheet White 1220 x 2440mm

Hygiclad® Hygienic Sheet is designed to provide an effective clean and hygienic surface protection. They are ideal for cleanrooms, washrooms and other areas where a simple wash-down surface is required. The Hygiclad® standard sheet offers exceptional strength and impact resistance for high traffic hard wearing areas. Bronze Tint for shading and glare reduction Virtually Unbreakable Easy to trim or cut to size Protected from UV light and discolouration Lightweight Suitable for use as cladding or glazing Easy to drill for fixing Note: This item is made-to-measure and is non-returnable. Samples available if required to verify suitability

Ibstock Brick Ivanhoe Olde Village – Pack Of 430

Red Multi Sanded Crease-textured Stock Facing Brick. Order In Singles. See Tech Spec For Pack Quantity. Durable – Can Be Used In Most Masonry Situations

4Trade Hinge 2 Ball Bearing 100 x 75 x 3mm Polished Ss Grade 13 Bsen 1935 CE Pk of 3

Ideal for hanging doors in and around the home Smooth operation PK of 3

Plaut Redwood Ledged Braced Door 2032 x 813 x 40mm

This ledged and braced door is constructed using quality tongue and grooved redwood board, it is ideal for utilitarian uses Doors are unfinished and require fully finishing on site to protect and prevent the ingress of moisture, which can cause warping. Does not include door furniture. Door furniture sold separately. A traditional designed redwood door ideal for utilitarian uses Ledged and braced construction using quality tongue and grooved redwood board Can be trimmed up to a maximum of 12mm on top and bottom edge only – any reduction should be removed evenly from each edge It is recommended that 3 hinges should be fitted to all doors weighing more than 20kg and doors where large differences of temperature or humidity on opposing faces can be expected. Recessed furniture and locks must not be placed within 76mm (3″) of any r Supplied unfinished, seal and finish using at least 3 coats of a quality external paint or stain

Catnic Timber Frame Steel Lintel Standard Duty 1500mm CTF5

The timber frame lintel range consists of single element lintel with a sloping outer face and duplex corrosion protection, which provides built-in DPC. All timber frame models must be secured with restraint clips (not supplied) and a batten (not supplied) to prevent lateral deflection (twist) during the building stage. Duplex Corrosion Protection Built-in DPC Restraint clips Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths from 3000mm – 4800mm (including 4575mm but excluding 4500mm) Timber frame lintels should be suitable propped during construction.

4Trade Cylinder & Thumb Turn Euro Profile 35/35mm Satin

Euro cylinders with a thumbturn are used on PVCu doors and composite doors where a euro case has been fitted Provides controlled access via key and easy access via thumbturn from the internal side of the door The thumbturn operates the deadbolt for privacy purposes

Clark-Drain Manhole Cover and Frame Ductile Iron 450mm x 600mm

Clark-Drain 600 x 450mm clear opening ductile iron manhole cover and frame with B125 load rating classification. For use in pavement, driveways and precinct areas B125 loading class BS EN124 accredited Includes frame Slide out access Unique corner design to ensure correct orientation of cover Integral lifting key holes Kitemark certified

Catnic Timber Frame Steel Lintel Standard Duty 2700mm CTF5

The timber frame lintel range consists of single element lintel with a sloping outer face and duplex corrosion protection, which provides built-in DPC. All timber frame models must be secured with restraint clips (not supplied) and a batten (not supplied) to prevent lateral deflection (twist) during the building stage. Duplex Corrosion Protection Built-in DPC Restraint clips Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths from 3000mm – 4800mm (including 4575mm but excluding 4500mm) Timber frame lintels should be suitable propped during construction.

Wienerberger Facing Brick Denton Peak Mixed Red – Pack of 400

Extruded red bark textured rustic Facing Brick. Selected for its high quality aesthetic appearance Conforms to BS and EU Standards Durability meets F2 rating for severe exposure Low Salt Content – S2 Occasionally there can be a lead time on bricks from the manufacturer. If this is the case, we will let you know as soon as possible

Pitacs 6243YH 1.5mm 3CORE & Earth Cable Grey 100m

1.5mm 6243Y 3 Core & Earth Cable Grey 100m. BASEC approved. Suitable for higher load 2-way lighting circuits BASEC Approved 6423Y 3 Core & Earth Cable BS 6004:2012 Max. Rating: 240V, 14.5A Maximum operating temperature: 70¡C Flat for easy installation Easy to strip

4Trade Double Switched Socket 1 Gang 13 Amp

13 amp rated single socket. ASTA approved Single pole Fixings included

XL PATTERN 10 WHITE PRIMED DOOR 1981 X 838 X 35MM

White Primed Pattern 10 Solid Core Internal Door This contemporary Shaker design can be finished in any colour to match your home. Constructed from mixed materials including wood and man-made materials Engineered construction for greater resistance to warping, twisting and splitting than traditional timber doors. The door can be finished using water based paints, stain or varnish as they are not suitable for treatment with any type of oil, wax or polish Door furniture is sold separately Glazed versions of this door are also available The door may be trimmed by up to 12mm in height and 12mm in width. Any reductions must be removed equally from each edge.

H+H Celcon Standard Aerated Concrete Foundation Block 3.6N 300mm

Available in Standard Grade (3.6N/mm2) and High Strength Grade (7.3N/mm2). Foundation Blocks can be used to support 3 storey constructions. They are suitable for the support of solid or cavity walls, framed construction or suspended floors, including beam and block. Celcon Foundation Blocks can be laid below ground level without mortar perpends. Simply lay them with mortared horizontal bed joints and then butt them together to prevent the passage of vermin. Solar Grade can also be used below ground, All Celcon Foundation Blocks may also be used above ground, with appropriate finishes, for solid wall construction. All Celcon Foundation Blocks may also be used above ground, with appropriate finishes, for solid wall construction. Applications: Foundations and Solid Wall Construction